AR or ID? A clear path through unsafe situations.
GasTrack helps engineers understand the hierarchy of unsafe situations under the Gas Industry Unsafe Situations Procedure — Immediately Dangerous, At Risk, Not to Current Standard, or no unsafe classification identified.
Assess against the applicable criteria.
Work through the hierarchy from highest risk down. Where a higher-risk classification is met, that classification takes precedence. The engineer must assess the specific situation against the current Gas Industry Unsafe Situations Procedure, manufacturer instructions and relevant requirements.
Start
Fault or concern identified on site
Assess the situation against the applicable criteria. Where a higher-risk classification is met, that classification takes precedence.
Decision
Immediate danger to life or property?
Gas escape, CO release, major flue failure, fire risk
Immediately Dangerous
- Disconnect the appliance
- Make the installation safe
- Do not leave in use
Decision
Risk present that could become dangerous?
Incomplete combustion, minor flue defect, degraded seal
At Risk
- Leave with a written warning
- Rectify promptly
- May remain in use meanwhile
Decision
Falls short of current standards, but no danger?
Older installation, superseded requirements
Not to Current Standard
- Advise the customer
- No disconnection required
- Record the finding
No AR/ID classification identified
- No unsafe classification from the assessed criteria
- Record the outcome and findings
Professional disclaimer
GasTrack is a decision-support tool. Classification must be based on the specific circumstances, current industry procedures, applicable regulations, manufacturer instructions and the competent engineer's professional judgement.
What each classification means.
Immediately Dangerous
A fault that poses an immediate threat to life or property. The appliance is disconnected, made safe and must not be used.
At Risk
A fault that could become a danger. The appliance may remain in use with a warning, but must be rectified promptly.
Not to Current Standard
The installation falls short of current standards but presents no danger. Advise the customer and record the finding.
No AR/ID classification identified
No unsafe classification identified from the assessed criteria. Record the outcome and findings — this is not a certification of the installation.